Skip Headers
Oracle® Database Reference
10g Release 2 (10.2)

Part Number B14237-02
Go to Documentation Home
Home
Go to Book List
Book List
Go to Table of Contents
Contents
Go to Index
Index
Go to Master Index
Master Index
Go to Feedback page
Contact Us

Go to previous page
Previous
Go to next page
Next
View PDF

AQ_TM_PROCESSES

Property Description
Parameter type Integer
Default value 0
Modifiable ALTER SYSTEM
Range of values 0 to 10
Basic No

AQ_TM_PROCESSES enables time monitoring of queue messages. The times can be used in messages that specify delay and expiration properties. Values from 1 to 10 specify the number of queue monitor processes created to monitor the messages. If AQ_TM_PROCESSES is not specified or is set to 0, then the queue monitor is not created.

See Also:

Oracle Streams Advanced Queuing User's Guide and Reference for more information about this parameter and Advanced Queuing